Protection&Control Transmission Line Protection Busbar Protection Transformer Protection Circuit Breaker Protection Generator Protection Feeder Protection Capacitor Protection Motor Protection Transfer & Synchronization Arc Protection
Digital Substation PCS-221S Merging Unit PCS-221 Merging Unit PCS-222 Circuit Breaker Controller PCS-9250 AC Electronic CT/VT
Automation PCS-9700 Automation System PCS-9700 HMI Software PCS-9705 Bay Control Unit PCS-9705S Bay Control Unit PCS-9799 Station Manager PCS-9799S Station Manager PCS-9710 Remote Terminal Unit PCS-9710S Remote Terminal Unit PCS-9794 Protocol Converter PCS-9785 Satellite-Synchronized Clock PCS-9882 Ethernet Switch PCS-9882Rx DIN Rail Managed Ethernet Switch PCS-9882XD Managed Ethernet Switch PCS-9884 Managed Ethernet Switch Supporting HSR and PRP MUX-2M/64 Communication Interface
Phasor Measurement PCS-997S Fault Line Locator PCS-996S-G Phasor Data Concentrator PCS-996 Phasor Measurement Unit
Disturbance Fault Recording PCS-996RC Disturbance Fault Recorder PCS-996R Disturbance Fault Recorder PCS-986 Disturbance Fault Recorder PCS-9013 DFR Management System
Stability Control System PCS-992 Power Stability Control System PCS-993 Out-of-Step Controller PCS-994 Frequency & Voltage Controller PCS-994S Frequency and Voltage Controller
Power Grid Monitoring and Control PCS-9000 Energy Management System PCS-9000 Distribution Management System
Configuration Tool PCS-Torch MOT Tool PCS-Studio Configuration Tool PCS-Explorer IED Configuration & Debugging Tool PCS-SCD Configuration Tool PCS-COMM Configuration & Debugging Tool
Accessories MD1501 Series Auxiliary Relays MD1701 Series Test Blocks MD1701S Test Block
FACTS PCS-9580 Static Var Compensator PCS-9583 Static Synchronous Compensator PCS-9570 Series Compensation PCS-9590 DC De-Icer PCS-9578 Controllable Shunt Reactor PCS-8200 Unified Power Flow Controller PCS-9571 Fault Current Limiter PCS-9564A Dynamic Voltage Restorer PCS-9569 Shore Power System
HVDC PCS-8600 UHVDC Converter Valve System PCS-9550 LCC-HVDC Control and Protection System PCS-8100 VSC-HVDC IGBT Valve PCS-9520 VSC-HVDC Control and Protection System PCS-9510 Cooling System PCS-8300 High-voltage DC Circuit Breaker PCS-9250 DC Electronic CT/VT
PV & Wind Power Grid-Connection PCS-9700 Renewable Energy SCADA PCS-9726 Generation Management Unit PCS-9700F Power Forecast System PCS-9700R AGC/AVC
Battery Energy Storage System PCS-9567TU-1000/1250/1375/1575/1750 1500V Series Outdoor Power Conversion System PCS-8811CB Centralized energy storage system PCS-8812PB Liquid cooled energy storage cabinet PCS-8813CPB High voltage directly connected energy storage system PCS-9567A Power Conversion System PCS-9567C BESS Control Unit PCS-9700 Energy Storage System
Microgrid PCS-9617MG Microgrid Controller
Static Frequency Converter PCS-9575 Static Frequency Converter
Protection,Automation&Control DMS EMS Stability Control & WAMS Digital Substation
HVDC & FACTS De-Icing Unified Power Flow Controller (UPFC) Series Compensation Static Synchronous Compensator(STATCOM) Static Var Compensator (SVC) LCC-HVDC Transmission VSC-HVDC Transmission
Renewable & Microgrid Energy Storage System Microgrid PV Generation SFC
Power Generation Pumped Storage Power Plant Nuclear Power Plant Hydro Power Plant Thermal Power Plant
Transmission System AC Transmission LCC-HVDC Transmission VSC-HVDC Transmission
Distribution System Distribution Network
Industrial Consumer Urban Track Traffic Electrified Railway Oil & Petrochemical Metals & Mining
HOME PRODUCTS Protection,Automation & Control Protection&Control Transfer & Synchronization
The PCS-9655 high speed transfer device is used in power plants to ensure the continuous and reliable power supply for busbars.
In normal operation, the power supply of busbar is provided by the main power supply branch, and the standby power supply is ready for switching. If the circuit breaker CB3 is closed, the standby power supply is in hot standby state; if the circuit breaker CB3 is opened, the standby power supply is in cold standby state.
If the main power supply has fault, the PCS-9655 will trip circuit breaker “CB1”, and the voltage of busbar is lost. Due to the mechanical inertia of motor load of busbar, the composite feedback voltage of busbar is decaying gradually. In this procedure, if the standby power supply is put into service at an improper moment, the voltage difference between busbar residual voltage and standby power supply voltage will have a greater impact on other equipment in the power plant. Then the switching operation is failed, and the busbar voltage is absolutely lost.
The PCS-9655 high speed transfer device can select the optimal moment for switching the standby power supply into service to ensure the safety and reliability of switching operation.
Normal manual switching function
Accident switching function
Loss-of-busbar-voltage switching function
Circuit breaker unexpected tripping switching function
Undervoltage load shedding switching function
Switch-onto fault protection
Voltage and current drift auto adjustment
Self supervision
Voltage transformer supervision
Circuit breaker status monitoring
Circuit breaker control
64 Fault records and 64 Disturbance records
1024 SOE records, latest records of following elements state changing: operating abnormality alarm elements, selfcheck alarm elements, protection elements and binary input elements.