Protection&Control Transmission Line Protection Busbar Protection Transformer Protection Circuit Breaker Protection Generator Protection Feeder Protection Capacitor Protection Motor Protection Transfer & Synchronization Arc Protection
Digital Substation PCS-221S Merging Unit PCS-221 Merging Unit PCS-222 Circuit Breaker Controller PCS-9250 AC Electronic CT/VT
Automation PCS-9700 Automation System PCS-9700 HMI Software PCS-9705 Bay Control Unit PCS-9705S Bay Control Unit PCS-9799 Station Manager PCS-9799S Station Manager PCS-9710 Remote Terminal Unit PCS-9710S Remote Terminal Unit PCS-9794 Protocol Converter PCS-9785 Satellite-Synchronized Clock PCS-9882 Ethernet Switch PCS-9882Rx DIN Rail Managed Ethernet Switch PCS-9882XD Managed Ethernet Switch PCS-9884 Managed Ethernet Switch Supporting HSR and PRP MUX-2M/64 Communication Interface
Phasor Measurement PCS-997S Fault Line Locator PCS-996S-G Phasor Data Concentrator PCS-996 Phasor Measurement Unit
Disturbance Fault Recording PCS-996RC Disturbance Fault Recorder PCS-996R Disturbance Fault Recorder PCS-986 Disturbance Fault Recorder PCS-9013 DFR Management System
Stability Control System PCS-992 Power Stability Control System PCS-993 Out-of-Step Controller PCS-994 Frequency & Voltage Controller PCS-994S Frequency and Voltage Controller
Power Grid Monitoring and Control PCS-9000 Energy Management System PCS-9000 Distribution Management System
Configuration Tool PCS-Torch MOT Tool PCS-Studio Configuration Tool PCS-Explorer IED Configuration & Debugging Tool PCS-SCD Configuration Tool PCS-COMM Configuration & Debugging Tool
Accessories MD1501 Series Auxiliary Relays MD1701 Series Test Blocks MD1701S Test Block
FACTS PCS-9580 Static Var Compensator PCS-9583 Static Synchronous Compensator PCS-9570 Series Compensation PCS-9590 DC De-Icer PCS-9578 Controllable Shunt Reactor PCS-8200 Unified Power Flow Controller PCS-9571 Fault Current Limiter PCS-9564A Dynamic Voltage Restorer PCS-9569 Shore Power System
HVDC PCS-8600 UHVDC Converter Valve System PCS-9550 LCC-HVDC Control and Protection System PCS-8100 VSC-HVDC IGBT Valve PCS-9520 VSC-HVDC Control and Protection System PCS-9510 Cooling System PCS-8300 High-voltage DC Circuit Breaker PCS-9250 DC Electronic CT/VT
PV & Wind Power Grid-Connection PCS-9700 Renewable Energy SCADA PCS-9726 Generation Management Unit PCS-9700F Power Forecast System PCS-9700R AGC/AVC
Battery Energy Storage System PCS-9567TU-1000/1250/1375/1575/1750 1500V Series Outdoor Power Conversion System PCS-8811CB Centralized energy storage system PCS-8812PB Liquid cooled energy storage cabinet PCS-8813CPB High voltage directly connected energy storage system PCS-9567A Power Conversion System PCS-9567C BESS Control Unit PCS-9700 Energy Storage System
Microgrid PCS-9617MG Microgrid Controller
Static Frequency Converter PCS-9575 Static Frequency Converter
Protection,Automation&Control DMS EMS Stability Control & WAMS Digital Substation
HVDC & FACTS De-Icing Unified Power Flow Controller (UPFC) Series Compensation Static Synchronous Compensator(STATCOM) Static Var Compensator (SVC) LCC-HVDC Transmission VSC-HVDC Transmission
Renewable & Microgrid Energy Storage System Microgrid PV Generation SFC
Power Generation Pumped Storage Power Plant Nuclear Power Plant Hydro Power Plant Thermal Power Plant
Transmission System AC Transmission LCC-HVDC Transmission VSC-HVDC Transmission
Distribution System Distribution Network
Industrial Consumer Urban Track Traffic Electrified Railway Oil & Petrochemical Metals & Mining
HOME PRODUCTS Protection,Automation & Control Protection&Control Transfer & Synchronization
The PCS-9651 continuously monitors the power supply lines of load and provides automatic transfer logic from a main source to backup source. If a fault occurred in any of the power supply lines, the PCS-9651 can discriminate the abnormal state and switch over the load from the faulty line to the normal line, to guarantee the continuous power supply to the load. Up to four typical switching modes are provided for selection. Besides, the remote/local control function is integrated in the unit.
This device can fully support the IEC61850 communication protocol and GOOSE function, and can completely meet the demands of a modern digitalized substation.
Automatic transfer switch (ATS)
Remote/local control function
Circuit breaker status monitoring
Tripping circuit supervision (TCS)
VT circuit supervision (VTS)
Self diagnostic
Voltage drift auto adjustment
64 Operation reports
1024 supervision alarm records
1024 control operation records
1024 user operating logs
64 fault and disturbance records (FDR)
1024 latest SOE records
Up to four 10Base-T/100Base-TX (RJ45) ports or two 100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for non-time-critical message, IEC 60870-5-103 over TCP/IP or DNP 3.0
Two RS-485 rear ports with IEC 60870-5-103
Up to Six 100Base-FX ports with IEC 61850-9-2 Sampling Value and GOOSE for time-critical message
One RS-485 rear port for clock synchronization
One RS-232 rear port for printer
1 faceplate RJ45 port for testing and setting
Clock synchronization via pulse, IRIG-B and SNTP
The voltages inputs and external binary inputs connecting to breaker auxiliary contacts are used to detect the abnormal state.
It provides the RJ-45 faceplate port for testing and setting to make commissioning and maintenance easier.
The device could receive the analog values from conventional CT/VT and electronic CT/VT via merging unit.
The connector type can be selected as plug in/out terminal connector or screw terminal connector. The unique plug in/ out terminal connectors from the relay rear panel to the terminal blocks on the rack or cabinet makes the onsite commissioning and replacement much easier than the traditional screw terminals when you do the commissioning.
Various methods of GPS time synchronization are supported in this relay, including SNTP, IEEE1588 (V2), pulse per second (PPS) and IRIG-B synchronization.
The PCS-9651 is fully complied with IEC 61850 and provides the independent interfaces for station bus and process bus respectively, supporting IEC 61850-8-1 MMS , GOOSE and IEC 61850-9-2 Sampling Value.