LANGUAGE:
EN CN
RU

HOME PRODUCTS Protection,Automation & Control Protection&Control Generator Protection

SERVICES NEWS EVENT CALENDOR CONTACT US
PCS-985TE Transformer Relay
  • PCS-985TE is a kind of high performance numerical transformer protection device, which integrates main and backup protection into one device. It provides complete protection of a transformer in any voltage level, and is typically applied for startup/standby transformer or auxiliary transformer of power plant with multiple branches, and main transformer, etc.

    PCS-985TE provides up to 36 analog input channels including current and voltage inputs. The transformer protections are configurable. Ancillary functions of fault diagnostic, disturbance records, event records and communication function are integrated in the device.

  • Miscellaneous Transformer Protection
    • Fault detector (FR)

    • ŸVoltage and current drift auto adjustment.

    • ŸVT circuit supervision (VTS)

    • ŸCT circuit supervision (CTS)

    • ŸCT saturation detection

    • ŸSelf diagnostic

    • ŸGPS clock synchronization

    • ŸFault recorder

    • ŸIEC61850 MMS & GOOSE for station bus

    • ŸIEC60870-5-103 protocol

    • ŸMODBUS protocol

    • ŸDNP 3.0 protocol

    • ŸCurrent differential protection (87T)

    • Transformer restricted earth fault protection (64REF)

    • ŸOverexcitation protection (24)

    • ŸNegative-sequence Overcurrent protection (50/51Q)

    • ŸPhase overcurrent protection (50/51P)

    • ŸPhase overcurrent alarm elements (51PAlm)

    • ŸGround overcurrent protection (50/51G)

    • ŸPhase overvoltage protection (59P)

    • ŸPhase undervoltage protection (27P)

    • ŸResidual overvoltage protection (59G)

    • ŸOverfrequency protection (81O)

    • ŸUnderfrequency protection (81U)

    • ŸRate-of-frequency-change protection (81R)

    • ŸThermal overload protection (49)

    • ŸImpedance protection (21)

    • ŸBreaker failure protection (50BF)

    • ŸPole disagreement protection (62PD)

    • ŸBreaker flashover protection (50F)

    • ŸCurrent differential protection of generator-transformer unit (87GT)

    • ŸMechanical protection (MR)

    log on
    phone:
    password:
    Code:
    Register
    Register
    phone:
    password:
    E-mail:
    company:
    name:
    country:
    Code:
    Previous:PCS-985TI Transformer Relay Next:PCS-985U Voltage Injector Back to list

    © Copyright NR Electric Co., Ltd.
    All Rights Reserved.

    About us Service & Support Company Training Contact Us

    Solutions Power Generation Transmission System Distribution Network Industrial Consumer

    Products Protection,Automation&Control FACTS HVDC Renewable & Microgrid