HOME PRODUCTS Protection,Automation & Control Protection&Control Feeder Protection
The PCS-9613S differential relay is a protection, control and monitoring unit for the feeder line in all systems of which the neutral point is effectively grounded or not effectively grounded. With its flexibility and the powerful PCS-Studio configuration tool, the PCS-9613S offers future-oriented system solutions with high investment security and low operating costs.
Optical Pilot Channel (FO)
Current Differential Protection (87L)
Phase Overcurrent Protection (50/51P)
Earth Fault Overcurrent Protection (50/51G)
Negative-sequence Overcurrent Protection (50/51Q)
RMS Overcurrent Protection (50/51R)
Broken Conductor Protection (46BC)
Phase Overvoltage Protection (59P)
Residual Overvoltage Protection (59G)
Negative-sequence Overvoltage Protection (59Q)
Positive-sequence Overvoltage Protection (59Pos)
Phase Undervoltage Protection (27P)
Overfrequency Protection (81O)
Underfrequency Protection (81U)
Frequency Rate-of-change Protection (81R)
Reverse Power Protection (32R)
Undercurrent Protection (37)
Breaker Failure Protection (50BF)
Switch-on-to-Fault Protection (SOTF)
Thermal Overload Protection (49)
Arc Flash Protection (50L/NL)
Transfer Trip (TT)
Automatic Reclosure (79)
Fault Location (FL)
Switchgear control
Double point status synthesis
Remote/Local control mode switch
Interlocking logic for control
Direct control
Closing synchronism check
Switchgear trip counter
VT circuit supervision
CT circuit supervision
Self-diagnostic
DC power supply supervision
System frequency supervision
Event recorder including 1024 disturbance items, 1024 change-of-state events, 1024 supervision events, 256 control logs and 1024 device logs.
Disturbance recorder including 64 disturbance records with waveforms (The file format of disturbance recorder is compatible with international COMTRADE file).
Single line diagram representation in display
The integrated Phasor Measurement Unit (PMU) function of synchrophasor measurement is compatible with IEEE C37.118-2005, IEEE C37.118.1-2011, IEEE C37.118.2-2011 and IEEE C37.118.1a-2014.
Supporting time synchronization by IRIG-B signal
Supporting P Class or M Class measurement (user selectable)
Measurement of three-phase and single-phase voltage and current
Measurement of positive/negative/zero-sequence voltage and current
Calculation of active power, reactive power, system frequency, and rate-of-change of frequency (ROCOF)
Measurement of up to 32 binary status (user configurable)
Output of synchrophasor with timestamp, support of multiple protocols (TCP, TCP-UDP, UDP) and multiple data rates for maximum 4 clients (PDC)
U, I, P, Q, Cos
Positive, negative and zero sequences
Max.15th harmonics
Energy metering (active and reactive energies for import and export)
Power Quality Supervision (PQS) with Total Harmonic Distortion (THD), deviation and unbalance
DC analogue outputs (4~20mA, 0~10V, 0~5V or 0~20mA)
Support of various protocols
Ø Modbus
Ø DNP3
Ø IEC 60870-5-103
Ø IEC 61850 Ed1 & Ed2
Ø IEC 62439 Parallel Redundancy Protocol (PRP)
Ø IEC 62439 High-availability Seamless Ring (HSR) Redundancy Protocol
Ø IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
Support for digital substation
Ø Extendable quantity of communication interfaces
Ø Support of IEC 61850 MMS Server
Ø Support of IEC 61850-8-1 GOOSE
Ø Support of IEC 61850-9-2LE SV
Up to four 10Base-T/100Base-TX copper Ethernet ports
Up to four 100Base-FX optical Ethernet ports
Two RS-485 serial ports for communication or printer
One RS-485/TTL serial port for clock synchronization
One BNC port for clock synchronization