PCS-9671 Transformer Relay
  • PCS-9671 is a compact numerical relay for two-winding transformers. It can be utilized for reactor or stub-bus current differential protection. It also can be used to protect reactors or implemented as a stub current differential protection in a oneand- a-half breaker arrangement. The restraint current differential protection, unrestraint differential protection and restricted earth fault protection are provided.

    Comprehensive flexibility is provided via the modular hardware design, scalable function library, programmable logics, configurable I/Os and definable LEDs. This allows users to create customized schemes for specific projects. Two fixed LEDs and 18 configurable 3-color LEDs (Green/Yellow/Red) are provided. The relay is compatible with IEC 61850 station bus and process bus applications. It supports IEC 61850-8-1 MMS, GOOSE and IEC 61850-9-2 Sampling Value. The RJ-45 faceplate port is implemented in effort to make testing, setting, commissioning and maintenance easier.

  • Protection and Control Management Auxiliary Testing Functions
    • ŸRestraint current differential protection. (87T)

    • ŸUnrestraint current differential protection. (87UT)

    • ŸRestricted earth fault protection (64REF)

    • Inrush current blocking by 2nd and 3rd harmonic

    • ŸOverexcitation blocking by 5th harmonic

    • ŸCT saturation detection

    • ŸPhase overcurrent protection (50/51P)

    • ŸZero sequence overcurrent protection (50/51G)

    • ŸNegative sequence overcurrent protection (46)

    • ŸThermal protection (49)

    • ŸUndervoltage and overvoltage protection (27/59)

    • ŸZero sequence overvoltage protection (59G)

    • Negative sequence overvoltage protection (47)

    • ŸOverexcitation protection (24)

    • ŸCT circuit supervision. (CTS)

    • 1024 supervision alarm records, 1024 control operation records and 1024 user operation records

    • 64 fault and disturbance records

    • 1024 SOE records

    • Up to four 10Base-T/100Base-TX (RJ45) ports or two 100Base-FX ports with IEC 61850-8-1 MMS, IEC 60870-5- 103 over TCP/IP

    • Two RS-485 rear ports with IEC 60870-5-103

    • Up to six 100Base-FX ports with IEC 61850-9-2 Sampling Value and GOOSE

    • One RS-485 rear port for clock synchronization

    • One RS-232 rear port for printer

    • One faceplate RJ-45 port for testing and setting

    • Clock synchronization via pulse, IRIG-B and SNTP

    • Virtual tripping report generation and communication testing

    • ŸVirtual self-supervision report generation and communication testing.

    • ŸVirtual binary input state change report generation and communication testing.

    • ŸBinary output testing.

    • Manual triggering fault recording.

    log on
    phone:
    password:
    Code:
    Register
    Register
    phone:
    password:
    E-mail:
    company:
    name:
    country:
    Code:
    Previous:PCS-974 Mechanical Relay Back to list

    © Copyright NR Electric Co., Ltd.
    All Rights Reserved.

    About us Service & Support Company Training Contact Us

    Solutions Power Generation Transmission System Distribution Network Industrial Consumer

    Products Protection,Automation&Control FACTS HVDC Renewable & Microgrid