LANGUAGE:
EN RU CN
RU

HOME PRODUCTS Protection,Automation & Control Protection&Control Feeder Protection

SERVICES NEWS EVENT CALENDOR CONTACT US
PCS-9611 Feeder Relay
  • The PCS-9611 relay is a protection, control and monitoring unit for various applications (such as overhead line, underground cable and transformer etc.) on solidly ground, impedance grounded, Peterson coil grounded and ungrounded system. The PCS-9611 features a high performance functional library, programmable logic, configurable I/O and integrated frequency- tracking.

     

    The PCS-9611 is designed based on advanced multiprocessor platform, fully complying with IEC 61850 station bus & process bus, supporting IEC 61850-8-1 MMS, GOOSE and IEC 61850- 9-2 Sampling Value.

  • Communcation Monitoring and Metering Protection and Control

    Up to four 10Base-T/100Base-TX (RJ45) ports or two 100Base-FX ports with IEC 61850-8-1 MMS and GOOSE for non-time-critical message, IEC 60870-5-103 over TCP/IP or DNP 3.0

    Two RS-485 rear ports with IEC 60870-5-103

    Up to Six 100Base-FX ports with IEC 61850-9-2 Sampling Value and GOOSE for time-critical message

    One RS-485 rear port for clock synchronization

    One RS-232 rear port for printer

    1 faceplate RJ45 port for testing and setting

    Clock synchronization via pulse, IRIG-B and SNTP



    ŸMetering of current, voltage, active power, reactive power, power factor, energy, frequency, and harmonic.

    ŸCircuit breaker monitoring.

    ŸCT failure supervision.

    ŸVT failure supervision.

    ŸLine voltage failure supervision.

    ŸTripping circuit supervision.

    ŸSelf diagnostic.

    ŸFault Recorder.

    ŸTotal 1024 SOE, including tripping, alarm, binary input change and human operation reports.

    Total 64 oscillograms. (Compatible with COMTRADE format)

    ŸSix-stage overcurrent protection. (67P, 50P/51P)

    ŸSix-stage neutral/ground overcurrent protection. (67G, 50/51G)

    Four-stage sensitive earth fault protection. (67SG/51SG)

    ŸTwo-stage undervoltage protection and two-stage over voltage protection. (27/59)

    ŸOne-stage negative sequence overvoltage protection. (47)

    ŸTwo-stage zero sequence overvoltage protection. (59G)

    ŸFour-stage under-frequency protection, four-stage over- frequency protection and four-stage rate-of-change of frequency (81)

    ŸBreaker failure protection. (50BF)

    Ÿ4-shot three-pole auto-reclosing with sync-check and dead line/bus check. (79/25)

    ŸDead zone protection. (50DZ)

    ŸNegative sequence overcurrent protection (46)

    ŸBroken conductor detection. (46BC)

    ŸThermal overload element. (49)

    ŸUndercurrent protection. (37)

    ŸSwitch-onto-fault (SOTF) logic.

    Cold load pickup logic (CLP)

    ŸMechanical Protection

    ŸInterlocking logic for distribution busbar protection.

    ŸRemote and local tripping/closing of the breaker.

    ŸInterlocking logic of the breaker control.

    ŸVoltage and current drift auto adjustment.

    ŸFrequency tracking.

    ŸFault locator.

    log on
    phone:
    password:
    Code:
    Register
    Register
    phone:
    password:
    E-mail:
    company:
    name:
    country:
    Code:
    Next:PCS-9611S Feeder Relay Back to list

    © Copyright NR Electric Co., Ltd.
    All Rights Reserved.

    About us Service & Support Company Training Contact Us

    Solutions Power Generation Transmission System Distribution Network Industrial Consumer

    Products Protection,Automation&Control FACTS HVDC Renewable & Microgrid